472 research outputs found

    Some Economic Issues in Robinson–Patman Land

    Get PDF

    Laboratory spectroscopy in support of atmospheric measurements

    Get PDF
    Optical measurements of trace species in the atmosphere require precise, accurate spectroscopic data for the molecules under study. This laboratory exits to provide high quality spectroscopic data for the interpretation of data from existing satellite, balloon, ground, and aircraft instruments, as well as to provide sufficient data to assess the feasibility of new instruments

    Ground-based lidar measurements of stratospheric ozone. The NASA/GSFC stratospheric ozone lidar trailer experiment STROZ LITE

    Get PDF
    The major research objective is the measurement of high precision vertical profiles of ozone between 20-40 kilometers. The precision is such that the instrument should be capable of detecting a small trend (on the order of less that 1 percent per year) over a 5-10 year period. Temperature was measured between 30 and 365 km. The Goddard Space Flight Center (GSFC) mobile lidar was installed at Table Mountain and a comparison between it and the permanent Jet Propulsion Laboratory (JPL) lidar was made over the course of about 3 weeks. The lidars agreed very well between 20 and 40 km, and under certain conditions up to 45-47 km. There were several anomalies that both lidars followed very well. Agreement with Rocket Ozonesonde (ROCOZ) and electrochemical concentration cell (ECC) sondes was also very good

    The GEEC2 spectroscopic survey of Galaxy Groups at 0.8<z<10.8<z<1

    Full text link
    We present the data release of the Gemini-South GMOS spectroscopy in the fields of 11 galaxy groups at 0.8<z<10.8<z<1, within the COSMOS field. This forms the basis of the Galaxy Environment Evolution Collaboration 2 (GEEC2) project to study galaxy evolution in haloes with M1013MM\sim 10^{13}M_\odot across cosmic time. The final sample includes 162162 spectroscopically--confirmed members with R50R50 per cent complete for galaxies within the virial radius, and with stellar mass Mstar>1010.3MM_{\rm star}>10^{10.3}M_\odot. Including galaxies with photometric redshifts we have an effective sample size of 400\sim 400 galaxies within the virial radii of these groups. We present group velocity dispersions, dynamical and stellar masses. Combining with the GCLASS sample of more massive clusters at the same redshift we find the total stellar mass is strongly correlated with the dynamical mass, with logM200=1.20(logMstar12)+14.07\log{M_{200}}=1.20\left(\log{M_{\rm star}}-12\right)+14.07. This stellar fraction of  1~\sim 1 per cent is lower than predicted by some halo occupation distribution models, though the weak dependence on halo mass is in good agreement. Most groups have an easily identifiable most massive galaxy (MMG) near the centre of the galaxy distribution, and we present the spectroscopic properties and surface brightness fits to these galaxies. The total stellar mass distribution in the groups, excluding the MMG, compares well with an NFW profile with concentration 44, for galaxies beyond 0.2R200\sim 0.2R_{200}. This is more concentrated than the number density distribution, demonstrating that there is some mass segregation.Comment: Accepted for publication in MNRAS. The appendix is omitted due to large figures. The full version will be available from the MNRAS website and from http://quixote.uwaterloo.ca/~mbalogh/papers/GEEC2_data.pdf. Long data tables are available from MNRAS or by contacting the first autho

    Oxidative stress and cardiovascular risk in type 1 diabetes mellitus: Insights from the DCCT/EDIC study

    Get PDF
    Background--Hyperglycemia leading to increased oxidative stress is implicated in the increased risk for the development of macrovascular and microvascular complications in patients with type 1 diabetes mellitus. Methods and Results--A random subcohort of 349 participants was selected from the DCCT/EDIC (Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications) cohort. This included 320 controls and 29 cardiovascular disease cases that were augmented with 98 additional known cases to yield a case cohort of 447 participants (320 controls, 127 cases). Biosamples from DCCT baseline, year 1, and closeout of DCCT, and 1 to 2 years post-DCCT (EDIC years 1 and 2) were measured for markers of oxidative stress, including plasma myeloperoxidase, paraoxonase activity, urinary F2α isoprostanes, and its metabolite, 2,3 dinor-8 iso prostaglandin F2α. Following adjustment for glycated hemoblobin and weighting the observations inversely proportional to the sampling selection probabilities, higher paraoxonase activity, reflective of antioxidant activity, and 2,3 dinor-8 iso prostaglandin F2α, an oxidative marker, were significantly associated with lower risk of cardiovascular disease (-4.5% risk for 10% higher paraoxonase, P \u3c 0.003; -5.3% risk for 10% higher 2,3 dinor-8 iso prostaglandin F2α, P=0.0092). In contrast, the oxidative markers myeloperoxidase and F2α isoprostanes were not significantly associated with cardiovascular disease after adjustment for glycated hemoblobin. There were no significant differences between DCCT intensive and conventional treatment groups in the change in all biomarkers across time segments. Conclusions--Heightened antioxidant activity (rather than diminished oxidative stress markers) is associated with lower cardiovascular disease risk in type 1 diabetes mellitus, but these biomarkers did not change over time with intensification of glycemic control. © 2018 The Authors

    Importance of a Priori Vertical Ozone Profiles for TEMPO Air Quality Retrievals

    Get PDF
    Ozone (O3) is a toxic pollutant which plays a major role in air quality. Typically, monitoring of surface air quality and O3 mixing ratios is conducted using in situ measurement networks. This is partially due to high-quality information related to air quality being limited from space-borne platforms due to coarse spatial resolution, limited temporal frequency, and minimal sensitivity to lower tropospheric and surface-level O3. The Tropospheric Emissions: Monitoring of Pollution (TEMPO) satellite is designed to address the limitations of current space-based platforms and to improve our ability to monitor North American air quality. TEMPO will provide hourly data of total column and vertical profiles of O3 with high spatial resolution to be used as a near-real-time air quality product. TEMPO O3 retrievals will apply the Smithsonian Astrophysical Observatory profile algorithm developed based on work from GOME (Global Ozone Monitoring Experiment), GOME-2, and OMI (Ozone Monitoring Instrument). This algorithm is suggested to use a priori O3 profile information from a climatological data-base developed from long-term ozone-sonde measurements (tropopause-based (TB-Clim) O3 climatology). This study evaluates the TB-Clim dataset and model simulated O3 profiles, which could potentially serve as a priori O3 profile information in TEMPO retrievals, from near-real-time data assimilation model products (NASA GMAO's (Global Modeling and Assimilation Office) operational GEOS-5 (Goddard Earth Observing System, Version 5) FP (Forecast Products) model and reanalysis data from MERRA2 (Modern-Era Retrospective analysis for Research and Applications, Version 2)) and a full chemical transport model (CTM), GEOS-Chem. In this study, vertical profile products are evaluated with surface (0-2 kilometers) and tropospheric (0-10 kilometers) TOLNet (Tropospheric Ozone Lidar Network) observations and the theoretical impact of individual a priori profile sources on the accuracy of TEMPO O3 retrievals in the troposphere and at the surface are presented. Results indicate that while the TB-Clim climatological dataset can replicate seasonally-averaged tropospheric O3 profiles, model-simulated profiles from a full CTM resulted in more accurate tropospheric and surface-level O3 retrievals from TEMPO when compared to hourly and daily-averaged TOLNet observations. Furthermore, it is shown that when large surface O3 mixing ratios are observed, TEMPO retrieval values at the surface are most accurate when applying CTM a priori profile information compared to all other data products
    corecore